SterilEnz® OEM Assemblies
SterilEnz®-II/A connectors were requested specifically by our OEM clients. They are a complete end fitting system which is delivered fully assembled & pressure tested. SterilEnz®-II/A Eliminates the chance of leaks and contamination at the end user level due to misaligned parts. While in use, and during disassembly, the pre-attached gaskets virtually eliminates operator error.

Home > SterilEnz® > SterilEnz® OEM Assemblies
Maintain the Sterility of All Components with SterilEnz® Assemblies
Pre-Gasketed & Sealed: LDPE Adapters
SterilEnz® Assemblies are the ultimate solution for critical applications where the sterility of the entire assembly (i.e. fitting, gasket, clamp & endcap) must be maintained . The SterilEnz® overwrap pouch provides a hermetic environment for all the critical components, thereby keeping contamination far away from your process. Some of the features and benefits are listed below:- Pre-Attached Gaskets: Our integrated pre-attached gasket requires no handling - hence it can't be dropped or mis-aligned during use.
- Integrity: Each part is individual integrity tested to insure correct assembly and alignment. Misaligned parts will leak, thereby jeopardizing your process.
- Mono-Barb Design: Won't leak or blow-off like stepped barbs can.
- Tamper Proof: In order to access the system, the pouch must be removed, this provides a perfect tamper evident solution to guard your process.
- Gamma-Stable: For use in irradiated disposable systems.
- ADCF Certifed: SterilEnz® Assemblies are animal derived component free.
SterilEnz® is a registered trademark of PAW BioScience Products, Inc.
| Part Number | Description | Case Qty. | Drawing/ Manual |
|---|
SterilEnz®-II/A - Technical Specifications (conducted on finished goods, post gamma)
| USP <88>: Class VI Biological reactivity tests, in vivo |
| USP <87>: Cytotoxicity, MEM Elution, in vitro |
| USP <661>: Physicochemical Test for Plastics |
| USP <1207>: Sterile Product Packaging - Integrity Evaluation, via microbial immersion |
| ASTM F756-00 : Rabbit Blood Cell Hemolysis |
| SterilEnz®-II/A are certified ADCF (animal derived component free). |
| All SterilEnz®-II/A products are assembled inside a certified ISO 5 (Class 100) environment |
| All SterilEnz®-II/A products are 100% integrity tested during manufacture to insure correctness of assembly and proper seating of all components. |
Sterilization Methods
| Gamma irradiation | Up to 50 kGy | Autoclave | Not suitable for autoclaving, use SterilEnz®-II/AT |
General Operating Specifications
| Part Number | Hose Barb | Flange | Max Operating Pressure |
Max Operating Temperature |
|---|---|---|---|---|
| 2A-408-TC-5X5 | 1/4" | Mini Sanitary | 60 psi | -20C to 50C |
| 2A-608-TC-5X5 | 3/8" | Mini Sanitary | 60 psi | -20C to 50C |
| 2A-812-TC-5X5 | 1/2" | Mini Sanitary | 60 psi | -20C to 50C |
| 2A-416-TC-6X8 | 1/4" | 1"/1.5" | 40 psi | -20C to 50C |
| 2A-616-TC-6X8 | 3/8" | 1"/1.5" | 40 psi | -20C to 50C |
| 2A-816-TC-6X8 | 1/2" | 1"/1.5" | 40 psi | -20C to 50C |
| 2A-1216-TC-6X8 | 3/4" | 1"/1.5" | 40 psi | -20C to 50C |